Skip to content

System Parameters Page ​

The system parameters page controls the software operation by setting global parameters.

Title Bar ​

NameDescription
System ParametersDisplays the name of the current page, along with maximize and close buttons

Basic ​

Parameter NameParameter RangeDefault ValueDescription
Automatically load project on startuptrue/falsefalsetrue: The AI-Vision software opens the specified project after launching
Automatically start HMI on startuptrue/falsefalsetrue: The AI-Vision software opens the HMI interface of the specified project after launching
Automatically start execution after startuptrue/falsefalsetrue: The AI-Vision software runs the specified project cyclically after launching
Automatically start execution after a delay (ms)>01000After the AI-Vision software launches, it waits for the set time and then runs the specified project cyclically
Effective condition: Automatically start execution after startup = true
Default project opening addressSet the path of the project to be automatically loaded
Effective condition: Automatically load project on startup = true
Default program nameSet the name of the program to be executed first in the project

General ​

Parameter NameParameter RangeDefault ValueDescription
Running modeNormal/Extreme speedNormalNormal: The IM image window on the main interface performs rendering normally
Extreme speed: The IM image window on the main interface does not perform rendering
Note: Extreme speed mode improves software running performance without affecting result calculation
Debugtrue/falsefalsetrue: The software prints debug information to the log file
false: The log file only records non-Debug type information
Note: The log file path is 'installation directory/.log'
Decimal places3-63The number of decimal places for float-type numbers displayed on the software interface
Note: This only affects the interface display and not the result calculation

Theme ​

Parameter NameParameter RangeDefault ValueDescription
BackgroundDaily/NightNightChange the background color of the software
Primary colorIris blueChange the theme color of the software

Image ​

Parameter Name
Parameter RangeDefault ValueDescription
Rendering modeSampling/DetailedSamplingSampling: The IM image window on the main interface renders point clouds by downsampling to 1 million points
Detailed: The IM image window on the main interface renders all points of the point cloud
Note: Detailed rendering will affect rendering performance
Mesh constructionMinimum/Medium/MaximumMinimumMinimum: The number of points used for mesh/surface rendering of point clouds is 1 million
Medium: The number of points used for mesh/surface rendering of point clouds is half of the total points
Maximum: The number of points used for mesh/surface rendering of point clouds is the total number of points

AI-Vision, Making 3D Measurement Easier