Skip to content

System Parameters Page

The system parameters page controls the software operation by setting global parameters.

Title Bar

NameDescription
System ParametersDisplays the name of the current page, along with maximize and close buttons

Basic

Parameter NameParameter RangeDefault ValueDescription
Automatically load project on startuptrue/falsefalsetrue: The AI-Vision software opens the specified project after launching
Automatically start HMI on startuptrue/falsefalsetrue: The AI-Vision software opens the HMI interface of the specified project after launching
Automatically start execution after startuptrue/falsefalsetrue: The AI-Vision software runs the specified project cyclically after launching
Automatically start execution after a delay (ms)>01000After the AI-Vision software launches, it waits for the set time and then runs the specified project cyclically
Effective condition: Automatically start execution after startup = true
Default project opening addressSet the path of the project to be automatically loaded
Effective condition: Automatically load project on startup = true
Default program nameSet the name of the program to be executed first in the project

General

Parameter NameParameter RangeDefault ValueDescription
Running modeNormal/Extreme speedNormalNormal: The IM image window on the main interface performs rendering normally
Extreme speed: The IM image window on the main interface does not perform rendering
Note: Extreme speed mode improves software running performance without affecting result calculation
Debugtrue/falsefalsetrue: The software prints debug information to the log file
false: The log file only records non-Debug type information
Note: The log file path is 'installation directory/.log'
Decimal places3-63The number of decimal places for float-type numbers displayed on the software interface
Note: This only affects the interface display and not the result calculation

Theme

Parameter NameParameter RangeDefault ValueDescription
BackgroundDaily/NightNightChange the background color of the software
Primary colorIris blueChange the theme color of the software

Image

Parameter Name
Parameter RangeDefault ValueDescription
Rendering modeSampling/DetailedSamplingSampling: The IM image window on the main interface renders point clouds by downsampling to 1 million points
Detailed: The IM image window on the main interface renders all points of the point cloud
Note: Detailed rendering will affect rendering performance
Mesh constructionMinimum/Medium/MaximumMinimumMinimum: The number of points used for mesh/surface rendering of point clouds is 1 million
Medium: The number of points used for mesh/surface rendering of point clouds is half of the total points
Maximum: The number of points used for mesh/surface rendering of point clouds is the total number of points

AI-Vision, Making 3D Measurement Easier